STARTING THE BCW PUMP : - | ||||||||||
F.1 PRE START CHECKS BEFORE INITIAL STARTING OF THE PUMP | ||||||||||
1 Boiler Drum is filled & drum level is maintained on positive side (+200 mm) for starting first | ||||||||||
pump. | ||||||||||
2 SGECW System & BCW Booster Pump is in service. | ||||||||||
3 Emergency over head tank level OK. | ||||||||||
4 Ensure that pump & pump cooler is completely vented. | ||||||||||
5 Start permissive is available. | ||||||||||
6 LP cooling water valves are open and the cooling water flow is > 75 LPM. | ||||||||||
7 All other valves must be closed. | ||||||||||
8 LP & HP purge lines are charged and purge line valve to motor is in closed condition. | ||||||||||
9 Check for any water leakage from pump instruments, cooler vent, pump & motor assembly. | ||||||||||
10 With water filled, the insulation resistance measured at the terminal links, using a 1000V | ||||||||||
megger must exceed 200 mega ohms. | ||||||||||
START PERMISSIVE | ||||||||||
1 No Switchgear disturbance. | ||||||||||
2 Switchgear Available | ||||||||||
3 Drum N2 Vent Valves Closed. | ||||||||||
4 Motor Cavity Temp Not high (57° C). | ||||||||||
5 Suction Manifold / Casing DT not high (< 38° C). | ||||||||||
6 BCW P/P Cooling Water Flow Adequate (> 75 LPM). | ||||||||||
7 BCW P/P Not Tripped. | ||||||||||
8 Both Discharge v/v Stem open. | ||||||||||
9 When a boiler is started from cold, a minimum of two BCW pumps must be operated. It is | ||||||||||
normal practice to start all the three pumps before boiler light up | ||||||||||
Starting of pumps | ||||||||||
1 Start the first pump | ||||||||||
2 Motor current will drop from full starting current after few seconds to normal & there is no | ||||||||||
hunting in current. | ||||||||||
3 Ensuring Drum level is normal start second pump (after starting of pump it tends to dip). | ||||||||||
4 Differential pressure should rise immediately to approx. 3.1 kg/sec². | ||||||||||
5 Check with local operator about any abnormal sound from pump. | ||||||||||
6 Ensure for the standby pump that DT between pump casing & boiler water is within 56° C. | ||||||||||
7 Caution –If motor fails to start after 5 seconds, press stop button & do not attempt to | ||||||||||
start the pump for 20 minutes. | ||||||||||
FOR STANDBY BCW PUMP: | ||||||||||
1 Close the service valve in pump jumper line & open the pump discharge by-pass valve. This | ||||||||||
ensures that as the boiler heats up, a flow passes from the discharge legs to the pump case & | ||||||||||
impeller. | ||||||||||
2 Check the motor cavity temperature is not exceeding 49 ° C. | ||||||||||
3 In such a case take the pump in service & close pump discharge by-pass valve & open the | ||||||||||
pump jumper line service valve. | ||||||||||
ISOLATION PROCEDURE | ||||||||||
There is no provision to isolate the pump in boiler lighted up condition as no isolation | ||||||||||
v/v is provided in suction line, only two manual v/v are provided in the two discharge | ||||||||||
lines. | ||||||||||
PROTECTIONS | ||||||||||
1 PUMP Motor Cavity Temperature Very High with a time delay of 5 sec (> 60 ° C). | ||||||||||
2 Discharge Valve Stem-1 not open | ||||||||||
3 Discharge Valve Stem-2 not open |