1)
Mill Operating Parameters and
Operation procedure: -
Ø
Maintain
Mill outlet temperature-> 55 C
Ø
Mill
inlet temperature -> not more than 180 C
Ø
Observe
all 4 coal pipe temperature of Mills with biomass regularly. In case of any
deviation from rest of the pipes (any abrupt rise or fall), stop the mill and
give PTW for inspection.
Ø
Pre
start and post shutdown purging of mill is mandatory.
Ø
Continuous
monitoring of mill parameters most importantly mills inlet air temperature, mill
outlet temperature, mill current and mill DP.
Ø
Mill
inlet temperature should not be more than 180 C in any case
Ø
Mill
reject system to be kept under observation continuously
Ø
Operator
should be deployed at local for monitoring in wake of fire hazard.
Ø
In
case of fire, mill should be tripped and steam inerting should be done
immediately by opening steam interting motorized valve, keeping watch on
furnace pressure. Fire tender may also
be used if required.
Ø
Clinkering
and slagging tendency to be observed from local as well as from rise in SH zone
FG temperature. Soot blowing and LRSB to be done accordingly.
Change
over to Biomass mode and vice-versa
For operator
ease Biomass On/OFF buttons have been provided on individual Mill screen.
Whenever Biomass ON is selected on screen then following changes happen in the
Mill logics-:
1.
Mill
temperature control by CAD (cold air damper) of the mill shifts to Mill inlet
temperature control as per the Inlet temperature set point.
2.
Mill
HAG (hot air Gate) will close on protection if Mill inlet temperature reaches
195 deg. Alarm for Mill inlet temperature is provided at 185 deg.
3.
HAG
(hot air gate) protection at mill outlet temperature 95 deg will also remain in
service irrespective of Biomass ON/OFF mode.
Changeover
to Biomass mode ON mode:
1.
Put
the CAD& HAD control to manual mode.
2.
Ensure
the set value for Mill temperature to 170-175 deg.
3.
Maintain
the position of HAD & CAD so as to bring the actual Mill inlet temperature
in the set value range. Wait for temperature stabilization
4.
Select
Biomass ON button.
5.
Put
CAD & HAD in auto.
6.
Mill
CAD control will shift to Mill inlet temperature.
Changeover to
Biomass OFF mode:
1. Put the CAD& HAD control to
manual mode.
2. Bring the set value of Mill
temperature near to actual running Mill outlet temperature by manually
adjusting the Mill HAD/CAD.
3. Select Biomass OFF mode, CAD control
will shift to Mill outlet temperature.
4. Put CAD & HAD in auto.
2)
Actions
to be taken in a milling system having fire during Biomass firing
Do’s
Ø
Call the CISF fire personnel for
immediate assistance.
Ø
Increase
the feeder speed to maximum and dump the coal to mill for few minutes.
Ø
Stop
the feeder after few minutes.
Ø
Close
HAG from control room and CAG & Mill seal air valve from local.
Ø
If
the pulverizer temperature continues to rise, admit inert steam by opening the
motorized steam inerting valve from control room.
Ø
If
fire occurs in the feeder then, close the feeder, seal air valve and open the
hydrant valve provided near individual feeder.
Don’ts
Ø
Do
not admit cold primary air in order to cool the mill.
Ø
Do
not expose any part of the mill (roller, scrapper chamber and tramp iron gate
for any inspection until the mill temp comes down to normal value).