AIR-PREHEATER MOTOR TRIPS/ AIR MOTOR DOES NOT START
AIR-PREHEATER MOTOR TRIPS/ AIR MOTOR DOES NOT START:
LIKELY CAUSES
· Motor may trip on overload.
· Power supply to the motor failed.
· Air motor failure or solenoid failure
· No compressed air available.
· Lube oil system fail.
· Some foreign material fallen on the APH & got stuck.
· Seal of the APH has got disturbed.
PLANT RESPONSE
LIKELY CAUSES
· Motor may trip on overload.
· Power supply to the motor failed.
· Air motor failure or solenoid failure
· No compressed air available.
· Lube oil system fail.
· Some foreign material fallen on the APH & got stuck.
· Seal of the APH has got disturbed.
PLANT RESPONSE
· Rapid fall of hot air temperature on one side.
· Rapid rise of gas temperature of stopped APH.
· Possibility of deformation of APH.
· Alarm at ECP/ DCS electrical motor stop- appears.
· Furnace draft will fluctuate due to ingress of cold FD air.
· Mill temp will drop as a result of drop in hot PA temperature.
OPERATOR ACTIONS
· Reduce boiler/generator load to 60% MCR gradually.
· Attempt for starting the electric motor, if the power has resumed or after resetting the over load.
· If the air motor has not started because of air solenoid problem open the bypass valve of the solenoid.
· Isolate affected air heater on the gas side first if all the attempts of starting the air motor or electric motor has failed. (Keep watch on draft)
· Isolate the affected APH at airside (keep watch on total airflow)
· Try to rotate air heater manually.
· Maintain generator load depending upon the parameters of the running AH.
· Watch hot air temperatures to mills
· Cut in oil burners, when load is reduced.
· Reduce corex to minimum.
· Checks lube oil system & restore lubrication.
PARAMETERS OF CONCERN
· Furnace draft.
· Mill o/l temp / hot PA temperature
Secondary air temperature.