Main Turbine Protection



TURBINE PROTECTION
1)         TG Lub oil pressure very low   (< 1.2 ksc)                
2)         Axial  shift  high (+/-1.0mm)
3)         HP  exhaust  temp. high          (> 500 degc)
4)         Condenser  vaccum  low(VSP)
5)         Condenser vaccum  low(FSP)  (> -0.7 ksc)  AND Turbine speed > 240 rpm
6)         HP casing  top/btm DT high  (> 100 degc) AND  Load >100MW
7)         IP casing front top/ btm DT high  (> 45 degc) AND             Load >100MW
8)         IP casing rear top/ btm DT high  (> 45 degc)  AND Load >100MW
9)         MFT                                                    S/W  &  H/W
10)       Generator  electrical protection           S/W  &  H/W
11)       Liquid in Generator Main leads top  (> 90 mm)
12)       Cold gas temp after cooler A&B high  (> 60 degc)
13)       Cold gas temp after cooler C&D high (> 60 degc)
14)       Primary water temp after cooler high (> 71 degc)
15)       Seal oil temp after cooler high   (> 55 degc)
16)       Hot air main exciter temp high  (> 80 degc)
17)       Stator winding flow very low (< 48 tph)
18)       Stator Main bushing  R flow low (< 1.33 tph)
19)       Stator Main bushing  S flow low (< 1.33 tph)
20)       Stator Main bushing  T flow low (< 1.33 tph)
21)       Turbine over speed trip (electrical)     (> 3330 rpm)
22)       Turbine over speed trip                       H/W
23)       Oil tank level very low ( 1150 mm from top)
24)       Turbine trip from desk operated
25)       Turbine trip from console operated
26)       Turbine trip from ATRS
27)       Emergency trip from HMI     
28)       Fire protection 1 or 2 operated
29)       Generator class B protection
30)       Low Vacuum Trip Device operated
31)       Manual Trip Device operated


1.2)      ALARM LIMITS
1)         TG Lub oil pressure very low (< 4.5ksc)
2)         Axial  shift  high (+/-0.5 mm)
3)         HP  exhaust  temp. high (> 485 degc)
4)         Condenser vaccum  low (FSP)  (> -0.8 ksc)
5)         HP casing  top/btm DT high  (> 90 degc)
6)         IP casing front top/ btm DT high  (> 30 degc)
7)         IP casing rear top/ btm DT high  (> 30 degc) 
8)         Cold gas temp after cooler A&B high   (> 55 degc)
9)         Cold gas temp after cooler C&D high   (> 55 degc)
10)       Stator winding flow very low (< 54 tph)
11)       Stator Main bushing  R flow low (< 1.4 tph)
12)       Stator Main bushing  S flow low (< 1.4 tph)
13)       Stator Main bushing  T flow low (< 1.4 tph)
14)       Turbine over speed   (> 3300 rpm)